RF GATEWAY and TERMINALS

SMART AUTOMATION SYSTEMS

RF GATEWAY ORF GW-H100

Oliptek manages centrally Oliptek RF Smart terminals centrally.

  • LCD Screen with web interface
  • Scenario system
  • Real-time watch
  • Oliptek device manager software
  • TCP / IP instruction set
  • URL-based instruction set

Physical Properties

It centrally manages Oliptek WiFi Smart terminals.

  • Product size (cm): 11.5 x 8.3 x 3.3
  • Weight: 120g
  • Case material: ABS
  • Working temperature: -20 / + 50
  • Protection class: IP44

RF Features

  • 300m diameter communication (open area)
  • 433.4 MHz – 473.0 MHz RF Communication
  • 1dBm (0.79mW) / 20dBm (100mW)
  • 117dBm (0.019pW) / -100dBm (10pW)

RF UNITS

RF terminals works with central management system by connecting to “Oliptek Rf Gateway” or “Oliptek RF Dongle”

RF Specifications

  • Communication at a distance of 150m (outdoor)
  • 433.4 MHz – 473.0 MHz RF Communication
  • 1dBm (0.79mW) / 20dBm (100mW)
  • 117dBm (0.019pW) / -100dBm (10pW)

Physical Properties:

  • Dimension: 35mm x 86mm x 59mm
  • Weight: 60g
  • Box Material: ABS
  • Operating Temprature: -20 / + 50

RF 2 Channel Relay

  • It has 2 relay outputs to be managed through central system.
  • 100mA Driver
  • Load current: 250VAC 16A 30V 16A
  • Coil voltage: 12VDC

RF Contact

  • It provides central monitoring of battery, water, electricity, gas, etc. systems that provide information via dry contact.
  • It sends the change information instantly to the center.

RF 3 Channel dimmer

  • Allows central control of RGB luminaires and 3-channel systems.
  • Supply: DC 12V – 24V
  • Data Output: DC 12V – 24V
  • Output: Each channel 5A
  • Max Output Power:
  • 180W (12V), 360W (24V)

RF Analog Input

  • It provides instant information to the central system by making analog measurements in the range of 0-10 V or 0-220V.
  • Works with inquiry system.
  • Single channel input
  • 8 bit resolution 0-10V DC or 0-220VAC measurement

RF Temperature, Humidity

  • Provides centralized monitoring of ambient temperature and humidity conditions. Works with inquiry system. Works with inquiry system.
  • Usable range: -55 to 125 ° C ± 0.5 ° C
  • Accurate information range: -10 ° C to + 85 ° C

RF Analog output

  • The value set with the RF command is taken from the analog output between 0-10V.
  • Single channel
  • 8 bit resolution
  • 0-10V DC control output